IO0061 - VENTICELL 22 R

- Accurate and quick laboratory oven

- 22-liter chamber volume

- Working temperature of from +10°C over ambient temperature up to 250°C300 °C

- Patented system of forced air flow in the chamber ensures a homogenous temperature profile for all processes of drying, heating and sterilizing materials in laboratories

- High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening

- Greater speed and accuracy of all tempering procedures ensures cost-saving operation; suitable especially for materials of high humidity, for demanding and accurate tests and processes

- Standard model with a Fuzzy-Logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display

- Wide range of optional equipment and accessories

- Output for a printer or PC connection

- Validation possibility (IQ , OQ)

Technical dataVenticell_22_standard_6

Interior of stainless steel material No. 1.4301

  • volume 22 l
  • depth 320 mm
  • width 240 mm
  • height 295 mm

Tray

  • standard equipment 2 pcs
  • storage area (w × d) 185×265 mm
  • racks 4 max. number
  • distance between guide rails 60 mm

Maximal weight of the load *)

  • inside the oven 25 kg/oven
  • per tray 10 kg/tray

Number of doors

  • 1 pcs

External dimensions (including door and handle)

  • depth 560 mm
  • diameter of the air branch outer/inner 52/49 mm
  • width 406 mm
  • height, incl. Feet (N) and Caster (K) 604 (N) mm

Package dimensions (three layers carton)

  • depth 665 mm
  • width 465 mm
  • depth 665 mm

Weight

  • gross 36 kg
  • net 31 kg

Working temperature **) (beginning of the regulation) - VENTICELL / VENTICELL plus

  • from 10 °C above ambient temp. to 250 / 300 °C

Temperature accuracy according to DIN 12 880 T2, at working temperature with closed air flap and door, > 50 °C

  • time variation cca (±) 0,3 °C
  • space deviation (±) % cca (±)% of the reached temperature 1,1 %

Time required to reach 250 °C with closed air flap and voltage 230 V

  • 28 min

Heat emission at 250 °C

  • 420 W

Air exchange speed at 250 °C

  • 45 cca/hour

Electricity - mains 50/60 Hz

  • max. power input 0,96 kW
  • nominal voltage 230 V
  • current 4,2 A
  • stand by 5 W

*) Approx. 50 % of the tray area can be filled while maintaining uniform air circulation inside the chamber.
**) Standard type is up to 250 °C, optional type is up to 300 °C.
Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage swing rate ventilator 100 %, defrost off, lighting off.

Changes in the design and make reserved.
The values may differ depending on specific charge and media parameters