EMA 502 CHNS-O Analyzer

IA0286

The EMA 502 Elemental Analyzer is the accurate and reliable solution for the determination of carbon, hydrogen, nitrogen, sulfur, and oxygen in various industrial sectors such as pharma and life science, organic chemistry, petrochemistry and energy, environmental,agronomy, food & feed. The EMA 502 offers consistent performance, versatility, ease-of-use and premium features for combustion analysis in accordance with international standards: AOAC, AACC, ASBC, ISO, DIN, IFFO, OIV, ASTM, EPA.

 

ONE SOLUTION FOR MULTIPLE ANALYTICAL CHALLENGES

    • All-in-one solution for the determination of Carbon, Hydrogen, Nitrogen,Sulfur, and Oxygen in organic matrices
    • Combustion and pyrolysis in a single analyzer avoiding the need for external modules

VERSATILITY AND PRODUCTIVITY

    • 30-position electronic autosampler expandable with extra 3 discsto ensure maximum productivity
    • Seamless switch from CHNS to O mode with the exclusive connection panel, without the need for external modules
  • Helium and Argon as carrier gas.

SUPERIOR RELIABILITY AND ACCURACY

    • The exclusive TCD of the EMA 502 ensures maximum accuracy and reliability
    • Precise determination from few ppm to 100% for solid, paste and liquid samples
    • The Gas Chromatographic technology ensures the complete separation of all elements and real-time peak data

UNMATCHED EASE-OF-USE

  • Intuitive operation with the powerful EMASoft™ software
  • Monitor the analytical process with the real-time graph
  • Benefit from a comprehensive reporting system

IMPROVED WORKFLOW

    • The exclusive connectivity to VELP Ermes Cloud Platform projects your lab to a data-rich environment with premium remote service support resulting in the highest system uptime.

TECHNICAL DATA

METHOD OF ANALYSIS:CHNS: Combustion
O: Pyrolysis
Display:CHNS: from 12 minutes
O: from 6 minutes
DETECTORTCD (Thermal Conductivity Detector)
SAMPLE WEIGHTUp to 100mg (depending on C content)
AUTOSAMPLER CAPACITYUp to 4 discs, 30 positions each (up to 117 samples)
PRECISION≤ 0.2 %
ANALYTICAL RANGE C0.001 – 20mg with Helium;
0.01 – 20mg with Argon
ANALYTICAL RANGE H0.001 – 5mg with Helium;
0.01 – 5mg with Argon
ANALYTICAL RANGE N0.001 – 20mg with Helium;
0.01 – 20mg with Argon
ANALYTICAL RANGE S385x780x416 mm (15.2x30.7x16.4 in)
ANALYTICAL RANGE O0.005 – 6 mg with Helium
ANALYTICAL RANGE S385x780x416 mm (15.2x30.7x16.4 in)
CARRIER GASHelium or Argon (Argon for CHN determination)
COMBUSTION / PYROLYSIS TEMPERATURECHNS: 1030°C
O: 1060°C
CONNECTIVITYUSB; RS232
ERMES CONNECTIONYes, via Wi-Fi or LAN connected to a PC
POWER INPUT570w
DIMENSIONS (W X H X D)500 x 510 x 410 mm (H 680 mm with autosampler)
19.7 x 20.1 x 16.1 in (H 26.8 with autosampler)
WEIGHT45 kg